AUXCNTEV=BOTH, EDGE=POS, CNTDIR=UP, CNTEV=BOTH
No Description
S1CDIR | Count Direction Determined By S1 |
CNTDIR | Non-Quadrature Mode Counter Direction Co 0 (UP): Up counter mode. 1 (DOWN): Down counter mode. |
EDGE | Edge Select 0 (POS): Positive edges on the PCNTn_S0IN inputs are counted in OVSSINGLE mode. Does not invert PCNTn_S1IN input in OVSSINGLE and EXTCLKSINGLE modes 1 (NEG): Negative edges on the PCNTn_S0IN inputs are counted in OVSSINGLE mode. Inverts the PCNTn_S1IN input in OVSSINGLE and EXTCLKSINGLE modes |
CNTEV | Controls When the Counter Counts 0 (BOTH): Counts up on up-count and down on down-count events. 1 (UP): Only counts up on up-count events. 2 (DOWN): Only counts down on down-count events. |
AUXCNTEV | Controls When the Aux Counter Counts 0 (BOTH): Counts up on both up-count and down-count events. 1 (UP): Counts up on up-count events. 2 (DOWN): Counts up on down-count events. |